Language model detects inconsistencies in X-ray reports in a controlled test

Paper / preprint arXiv cs.CL · Reported findings, not independently verified by us.

A fine-tuned language model detected mismatches between chest X-ray report statements and image-derived pathology scores more accurately than a rule-based method in a controlled test. The results suggest one way language models might help check medical text, but they do not establish performance in clinical practice.

Rad-Linter combines scores from a pretrained image classifier covering nine pathologies with a 1.5-billion-parameter language model. The model was fine-tuned with LoRA on 1,816 examples and checks whether the scores agree with the report. The comparison system was a rule-based baseline given the same reports and scores.

For the first evaluation, the researchers created 131 groups of four pairings, each combining two real reports with two score vectors from other patients. Each group contained two consistent and two inconsistent pairings. Since each report and score vector appeared in both conditions, neither input alone revealed the correct match. Rad-Linter achieved 98.5% accuracy per pair, compared with 80.5% for the rule baseline. It classified all four pairings correctly in 94.4% of groups, versus 56.5% for the baseline.

On a second set of 181 groups, which also included cases where automatic report labelers disagreed, pair accuracy was 93.4% versus 75.3%. The advantage was especially apparent when interpreting how findings were worded. The evaluation uses controlled pairings and automatically derived labels; the original paper provides details of the setup and further results: arXiv paper.

🇬🇧 https://arxiv.org/abs/2611.26492v1

Leave a Comment

The weekly brief: selected developments, projects and videos