Simulation models vein compression for robotic femoral access

Paper / preprint arXiv cs.RO · Reported findings, not independently verified by us.

A physics-based simulation can model vein compression during ultrasound-guided femoral access with substantially less computation. The results suggest it may be worth exploring as a supplement for training or online simulation of autonomous access systems.

The team evaluated NVIDIA Isaac Sim for Healthcare using a low-fidelity cylindrical phantom with known geometry and mechanical properties. A robot pressed the phantom. At every depth, the simulated artery was within five percentage points of the phantom; the vein was within three points through 11 millimeters of a total 25.4-millimeter press. The simulated vein also followed the physical phantom’s collapse behavior.

A selected setting cut solver time per frame from 29,700 milliseconds to 30.4 milliseconds while remaining within 1.03 points of the finest reference setting. Increasing solver work did not improve accuracy. The complete stack, including ultrasound and graphics rendering, took 56.4 milliseconds per frame.

A digital leg model seeded with realistic, literature-based mechanical properties showed greater compression of the vein than the artery at every tested setting. The work assesses technical feasibility, not performance in patients. The original paper provides further details on the setup, parameters, and results in the arXiv study.

🇬🇧 https://arxiv.org/abs/2611.12818v1

Leave a Comment

The weekly brief: selected developments, projects and videos